{"id":18359,"date":"2021-08-09T06:00:00","date_gmt":"2021-08-09T06:00:00","guid":{"rendered":"https:\/\/industrialwaterbrasil.com.br\/iwb\/?p=18359"},"modified":"2021-10-10T12:56:47","modified_gmt":"2021-10-10T12:56:47","slug":"por-que-o-controle-de-silica-fica-mais-restrito-para-caldeiras-de-alta-pressao","status":"publish","type":"post","link":"https:\/\/industrialwaterbrasil.com.br\/iwb\/por-que-o-controle-de-silica-fica-mais-restrito-para-caldeiras-de-alta-pressao\/","title":{"rendered":"Por que o controle de s\u00edlica fica mais restrito para caldeiras de Alta Press\u00e3o?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"18359\" class=\"elementor elementor-18359\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-572ed0d5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"572ed0d5\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7daf557f\" data-id=\"7daf557f\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\n\t\t<div class=\"elementor-element elementor-element-716f4b96 elementor-widget elementor-widget-text-editor\" data-id=\"716f4b96\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<p>S\u00edlica \u00e9 um item altamente incrustante, preocupante para todas as classes de caldeiras. Devido a sua caracter\u00edstica e necessidade de controle, a s\u00edlica \u00e9 referenciada pela norma ASME (American Society of Mechanical Engineers) com a norma indicando a concentra\u00e7\u00e3o m\u00e1xima para v\u00e1rias classes de press\u00e3o das caldeiras, ou seja, n\u00e3o \u00e9 um valor para todo o tipo de caldeira, esse valor m\u00e1ximo recomendado \u00e9 vari\u00e1vel e diminui conforme a press\u00e3o da caldeira aumenta.<\/p>\n<p><\/p>\n<p><\/p>\n<p>O impacto da s\u00edlica no tratamento de \u00e1gua de caldeiras, n\u00e3o \u00e9 o mesmo entre caldeiras de baixa e alta press\u00e3o. Em caldeiras de baixa press\u00e3o, por exemplo, uma caldeira de 10Bar, com tratamento adequado a recomenda\u00e7\u00e3o \u00e9 de trabalhar com limite m\u00e1ximo de 150ppm de s\u00edlica e a preocupa\u00e7\u00e3o com a eleva\u00e7\u00e3o do teor de s\u00edlica \u00e9 com a incrusta\u00e7\u00e3o. Teor de s\u00edlica acima desse valor deixa o sistema vulner\u00e1vel, com alta tendencia de forma\u00e7\u00e3o de incrusta\u00e7\u00f5es, impactando na troca t\u00e9rmica, gerando problemas operacionais, financeiros, al\u00e9m de depreciar a caldeira.<\/p>\n<h5><span id=\"docs-internal-guid-960b26fb-7fff-cbba-5e30-eb0ec4479038\" style=\"font-weight: normal;\"><span style=\"font-size: 11pt; font-family: Arial; color: #000000; background-color: transparent; font-weight: bold; font-style: normal; font-variant: normal; white-space: pre-wrap;\">Tubos de Caldeira incrustados<\/span><\/span><\/h5>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35854d6 elementor-widget elementor-widget-image\" data-id=\"35854d6\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"512\" src=\"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-2-768x512.jpg\" class=\"attachment-medium_large size-medium_large wp-image-18362\" alt=\"Tubos caldeira fogo tubular\" srcset=\"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-2-768x512.jpg 768w, https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-2-300x200.jpg 300w, https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-2-535x356.jpg 535w, https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-2.jpg 800w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Tubos caldeira fogo tubular<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b5af05 elementor-widget elementor-widget-text-editor\" data-id=\"7b5af05\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<p><span style=\"font-size: 16px;\">No caso de caldeiras de alta press\u00e3o, a preocupa\u00e7\u00e3o b\u00e1sica j\u00e1 \u00e9 outra, n\u00e3o \u00e9 com a incrusta\u00e7\u00e3o nos tubos internos da caldeira, mas sim com as turbinas que s\u00e3o alimentadas com o vapor proveniente da caldeira.<\/span><\/p>\n<p>Vimos que para uma caldeira de baixa press\u00e3o o limite recomendado \u00e9 de 150ppm, agora para uma caldeira de alta press\u00e3o essa recomenda\u00e7\u00e3o cai drasticamente para 8ppm, 2ppm, 1ppm, isso vai depender da press\u00e3o de opera\u00e7\u00e3o da caldeira. Por exemplo uma caldeira que trabalha que trabalha com 70Bar de press\u00e3o, o limite m\u00e1ximo de s\u00edlica dentro do sistema \u00e9 de 2ppm, al\u00e9m disso o monitoramento passa a ser r\u00edgido tamb\u00e9m no vapor gerado, com controles r\u00edgidos, onde os fabricantes de turbina recomendam teores abaixo de 0,01ppm.<\/p>\n<p>Isso \u00e9 necess\u00e1rio, pois nessa faixa de press\u00e3o ocorre o arraste vol\u00e1til, ou seja, a s\u00edlica presente na \u00e1gua volatiliza e flui junto com o vapor, depositando na turbina, isso \u00e9 extremamente prejudicial para a turbina, imagina uma turbina com deposi\u00e7\u00f5es, diminuindo a capacidade de gerar energia, impactando diretamente na receita da companhia.<\/p>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b75729 elementor-widget elementor-widget-image\" data-id=\"3b75729\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"768\" height=\"512\" src=\"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-3-768x512.jpg\" class=\"attachment-medium_large size-medium_large wp-image-18363\" alt=\"\" srcset=\"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-3-768x512.jpg 768w, https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-3-300x200.jpg 300w, https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-3-535x356.jpg 535w, https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-content\/uploads\/2021\/08\/Por-que-o-controle-de-si\u0301lica-fica-mais-restrito-para-caldeiras-de-Alta-Pressa\u0303o-3.jpg 800w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Turbina com dep\u00f3sitos de sais provenientes da caldeira<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6635b1b elementor-widget elementor-widget-text-editor\" data-id=\"6635b1b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<p>Para ter uma ideia em valores, o custo m\u00e9dio de uma manuten\u00e7\u00e3o de montagem e limpeza de uma turbina est\u00e1 na faixa de R$ 200.000,00 isso apenas para uma turbina, tem ind\u00fastrias que tem v\u00e1rias turbinas trabalhando com o mesmo vapor gerado.<\/p>\n<p>Agora some os custos de diminui\u00e7\u00e3o de energia gerada, parada e manuten\u00e7\u00e3o o equipamento e chegar\u00e1 em um n\u00famero na case de milh\u00f5es de reais.<\/p>\n<p>A concentra\u00e7\u00e3o de s\u00edlica dissolvida no vapor \u00e9 uma fun\u00e7\u00e3o da temperatura do vapor, do pH da \u00e1gua da caldeira e da concentra\u00e7\u00e3o de s\u00edlica na \u00e1gua da caldeira, por isso o conhecimento adequado em tratamento de \u00e1guas industriais \u00e9 essencial.<\/p>\n<p>O impacto da s\u00edlica no tratamento de \u00e1gua de caldeiras, n\u00e3o \u00e9 o mesmo entre caldeiras de baixa e alta press\u00e3o. Em caldeiras de baixa press\u00e3o, por exemplo, uma caldeira de 10Bar, com tratamento adequado a recomenda\u00e7\u00e3o \u00e9 de trabalhar com limite m\u00e1ximo de 150ppm de s\u00edlica e a preocupa\u00e7\u00e3o com a eleva\u00e7\u00e3o do teor de s\u00edlica \u00e9 com a incrusta\u00e7\u00e3o. Teor de s\u00edlica acima desse valor deixa o sistema vulner\u00e1vel, com alta tendencia de forma\u00e7\u00e3o de incrusta\u00e7\u00f5es, impactando na troca t\u00e9rmica, gerando problemas operacionais, financeiros, al\u00e9m de depreciar a caldeira.<\/p>\n<p><b>#tratamentodeagua<\/b> <b>#tratamentodeefluentes<\/b> <b>#caldeiras<\/b> <b>#torresderesfriamento<\/b> <b>#quimico<\/b> <b>#quimica<\/b> <b>#osmosereversa <\/b><b>#reuso<\/b> <b>#reusodeagua<\/b> <b>#engenhariaqu\u00edmica<\/b> <b>#engenhariamec\u00e2nica <\/b><b>#engenhariaeletrica<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><b>#engenhariadeprodu\u00e7\u00e3o<\/b> <b>#manutencao<\/b><span style=\"font-weight: 400;\">\u00a0<\/span><b>#engenharia<\/b> <b>#usinas #a\u00e7ucarealcool #a\u00e7\u00facar #alcool #utilidadesindustriais #vapor #meioambiente<\/b><\/p>\n<p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>S\u00edlica \u00e9 um item altamente incrustante, preocupante para todas as classes de caldeiras. Devido a sua caracter\u00edstica e necessidade de controle, a s\u00edlica \u00e9 referenciada pela norma ASME (American Society of Mechanical Engineers)&#8230;<\/p>\n","protected":false},"author":1,"featured_media":18361,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[102,99],"tags":[108,109],"class_list":["post-18359","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-duvidas","category-tratamento-de-agua","tag-caldeiras","tag-silica"],"_links":{"self":[{"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/posts\/18359","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/comments?post=18359"}],"version-history":[{"count":13,"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/posts\/18359\/revisions"}],"predecessor-version":[{"id":18385,"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/posts\/18359\/revisions\/18385"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/media\/18361"}],"wp:attachment":[{"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/media?parent=18359"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/categories?post=18359"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/industrialwaterbrasil.com.br\/iwb\/wp-json\/wp\/v2\/tags?post=18359"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}